Independent repair reference for LG home appliances. Not affiliated with LG Electronics.
REV 2026.07EN/FR

Solutions

Dryers

1 procedure · 12 codes

Vented, condenser and heat-pump. Airflow restriction is behind most of it.

DRDryersd80d90d95
Cutaway line drawing of a dryer vent duct running to a wall outlet, blocked with lint

LG dryer d80, d90 and d95: restoring airflow through the whole duct run

Clothes take two or three cycles to dry, the drum smells hot, and d80, d90 or d95 appears near the end of the cycle.

DifficultyEasy45–90 min

12 codes

Error codes

View all

Showing 12 / 12 codes

Codes vary by model year and platform. Always confirm against the manual for your exact model number before ordering parts.

CodeMeaningFirst checkProcedure
d80User-fixableMeaningExhaust duct is about 80% restricted: the dryer is warning, not stopping.First checkLint screen first, then the flexible hose behind the machine: it crushes when pushed back.Open guide
d90User-fixableMeaningExhaust duct is about 90% restricted. Drying times will have roughly doubled.First checkDisconnect the hose and run a two-minute air-fry cycle: strong airflow means the blockage is downstream.Open guide
d95User-fixableMeaningExhaust duct is about 95% restricted. Stop using the dryer: this is the fire-risk threshold.First checkClear the full run from machine to wall cap, including the exterior flap.Open guide
tE1Service call likelyMeaningThermistor 1 error: the inlet/heater temperature sensor is out of range.First checkA restricted duct cooks this sensor. Clear airflow first, then measure the thermistor.No procedure yet
tE2Service call likelyMeaningThermistor 2 error: the outlet/exhaust temperature sensor is open or shorted.First checkSensor connector at the blower housing; lint packs around it and pulls the terminal loose.No procedure yet
tE4Service call likelyMeaningThermistor 4 error: the compressor-side sensor on heat-pump models is faulty.First checkClean the heat-exchanger fins behind the lower flap before condemning the sensor.No procedure yet
dEUser-fixableMeaningDoor error: the drum door is not latching, or the switch has failed.First checkListen for the click as the door closes; no click means the strike plate has worn.No procedure yet
PSService call likelyMeaningPower supply error: the dryer saw a mains surge or a phase problem.First checkRemove extension leads and plug directly into the wall on its own circuit.No procedure yet
AEService call likelyMeaningAssembly / EEPROM communication error between the control and display boards.First checkUnplug for ten minutes. If it returns immediately, the main board needs replacing.No procedure yet
nPService call likelyMeaningNo power to the heater leg: one side of the 240 V supply is missing.First checkA tripped half of a double-pole breaker: the drum turns, the air stays cold.No procedure yet
F1Service call likelyMeaningComponent fault reported by the main board: usually a relay stuck closed.First checkDoes the drum heat when the cycle is off? That confirms a welded heater relay: unplug it now.No procedure yet
OEUser-fixableMeaningCondensate drain error on condenser and heat-pump dryers: the pump cannot clear the tray.First checkEmpty the water tank and clean its float; sludge on the float is the usual cause.No procedure yet